Examples of Errors During the Installation of Air Conditioners in Potentially Explosive Atmospheres

Explosion-hazardous zones require cooling that maintains a stable temperature without creating new ignition sources. The mere presence of an air conditioner approved for operation in an EX zone is insufficient; factors such as the mounting method, cable routing, enclosure sealing, installation site selection, and compliance with technical documentation are crucial. In many facilities, it is improper installation—rather than a defective unit—that leads to costly downtime or non-compliance with ATEX requirements

Incorrect Selection of Installation Zone

A common oversight is the installation of an EX-rated air conditioner in a location designated in the facility’s documentation as a zone different from the one specified by the manufacturer. In practice, this means a unit approved for Zone 2 end up near equipment operating in conditions corresponding to Zone 1. Such a configuration increases risk and automatically violates ATEX regulations. The choice of zone should be based on the actual hazard level, not on installation convenience. The manufacturer specifies the scope of approval not for interpretation, but for strict adherence without deviation.

Errors In The Installation of Penetrations and Seals

Air conditioners designed for hazardous (Ex) areas must create a tight seal between the interior of the control cabinet and the surrounding environment. In practice, many faults stem from improper sealing of cable entries and connections passing through the enclosure wall. Any leaks allow for gas exchange, which can lead to the accumulation of an explosive atmosphere in an area that should remain isolated.

ATEX-ready models offered by SMARTqube have strictly defined installation requirements regarding seals and penetrations. Failure to comply with these guidelines will result in the entire installation losing its protective properties. Sealing is not a cosmetic matter, but the foundation of the entire system’s operation.

Installation Location with Insufficient Airflow

Overheating and a drop in air conditioner performance may stem not from equipment defects but from equipment defects, but from improper installation. In hazardous areas, installations with restricted free airflow around the housing are particularly common; units are sometimes placed too close to pipelines, walls, or support structures, disrupting heat exchange.

Industrial air conditioners-including the ATEX ready ICEqube models offered by SMARTqube-are designed to provide stable cooling in demanding conditions. However, if the clearance specified by the manufacturer is not maintained, their performance is compromised. Consequently, the temperature inside the enclosure rises, and control equipment is forced to operate under extremely harsh conditions.

Ignoring the Required Internal Airflow Arrangement of the Cabinet

Many installers focus on the external mounting of the air conditioner while overlooking the need to maintain proper airflow direction inside the enclosure. In hazardous (Ex) areas, every detail matters. If cold air is directed toward an area where it should not accumulate, there is a risk of condensation and equipment malfunction.

In extreme cases, water vapor can eventually cause micro-damage to control boards. SMARTqube solutions feature designs that ensure precise airflow; however, this relies on correct installation and proper component placement within the enclosure.

Improper Cable Routing

In ATEX installations, any constriction, excessively twisted cable, or contact between cables and high-temperature surfaces can risk damaging the insulation. Yet, air conditioners in EX zones are often powered by haphazardly routed cables that pass near equipment generating heat or vibration. If proper cable glands are also missing, there is a risk of the system losing its seal.

ATEX-ready air conditioners require the use of certified cable glands and the maintenance of a stable cable layout. Routing cables haphazardly compromises the protective properties of the entire installation.

Improperly Installed Device Mounting

In potentially explosive atmospheres, vibrations can be intense, particuraly near pumps, mixers, or process units. Air conditioners are sometimes mounted on structures that are too lightweight or installed using brackets that do not meet the manufacturer’s specifications. Over time, such mountings can loosen, leading to casing damage or leaks.

While SMARTqube supplies air conditioners as complete solutions, installation stability depends on the actual setup. Improper mounting invalidates the certification of the entire unit.

Skipping Regular Servicing

Servicing units in EX zones involves more than just a general condition check; it entails inspecting seals, performing leak tests, checking connections, cleaning heat exchangers, and evaluating fan performance. If installers or users treat this process as a mere formality, the risk increases. Negligence leads to reduced efficiency, system overloads, and potential failures.

Installing an air conditioner in an explosion-hazardous zone requires strict adherence to manufacturer guidelines, proper planning, and precision execution. Installation errors compromise the system’s integrity and create situations that threaten production continuity. While SMARTqube solutions for EX zones-including ATEX-ready ICEqube air conditioners, offer a high level of safety, their effectiveness depends on correct installation and systematic maintenance.